Storm Water Management System for Townhouses South

 

By: Kelly Hommen, Elizabeth Lafferty (PM), Michael Murphy & Charles Stewart                                        

Advisers: Dr. M. Horst & Dr. V. Krstic

The College of New Jersey’s Townhouses South residences experience water infiltration and persistent dampness in their crawlspaces. Townhouses South is comprised of 26 individual units each of which has a crawlspace extending approximately 3 feet below the surface.  Of the 26 units, standing water was detected in the crawlspaces of 15 of them, and all but 6 have noticeable moisture. This moisture has contributed to the structural deterioration of the crawlspaces as well as the growth of mold.  This study is intended to determine the foremost cause of the water infiltration and propose a solution to maintain the structural integrity of the Townhouses.Through the use of geotechnical, hydrologic, and hydraulic analysis, data was collected to allow for analysis and the proposal of adequate solutions.  Geotechnical testing was conducted in accordance with ASTM standards, and soil was classified using Burmister classification system to produce a soil profile. The profile is comprised of four strata; the top three consist of brown sand with trace amounts of silt.  The final stratum, located seven feet below the surface, is brown sand with clayley silt.  The hydraulic conductivity of the first five feet of the soil profile was determined to be 0.001323 ft/min.  A ground water well was installed in close proximity to the most critical crawlspaces and extended to a depth of seven feet below the surface.  Although no groundwater table was detected, monitoring will continue. With the use of topographic maps, watershed properties were obtained and used in combination with rainfall estimates to predict the volume of infiltrated water for various return period storm events.  The computer modeling software HEC-HMS was utilized to complete this portion of the analysis.  During Senior Project II, designs to remediate this problem will be considered for future use. Potential solutions include an underground storm water collection and recycling system, regrading of the soil surrounding the townhouses, a rooftop rainwater catchment system, and a design for sump pumps in the crawlspaces.

Project Site

 

Contact

Armstrong Hall, Room 165
The College of New Jersey
P.O. Box 7718
2000 Pennington Rd.
Ewing, NJ 08628

609.771.2538
engineer@tcnj.edu

Top
Engineering Summer Camps for High School StudentsLearn More
+